最近PSCO關于手提泡沫槍的開具了不少缺陷,有國內(nèi)的,也有國外的,甚至出現(xiàn)了滯留缺陷!提醒同行注意,經(jīng)常開具的缺陷如下: 手提泡沫裝置缺陷是個古老缺陷,以前經(jīng)常出現(xiàn),現(xiàn)在老樹發(fā)新芽,喜迎第二春,大家還是要重點注意的! 對于手提泡沫槍的配備,最早條款,出現(xiàn)在: SOLAS1983修正案II-2章第6條: A portable foam applicator unit shall consist of an air-foam nozzle of an induct or type capable of being connected to the fire main by a fire hose, together with a portable tank containing at least 20l of foam-making liquid and one spare tank. The nozzle shall be capable of producing effective foam suitable for extinguishing an oil fire, at the rate of at least 1.5m3/minute. SOLAS2000修正案II-2第10.5.1條進行了修訂,對于內(nèi)設燃油鍋爐和燃油裝置的A類機器處所,應在每一鍋爐艙內(nèi)或鍋爐艙入口(in each boiler room or at an entrance outside of the boiler room)處配備一套手提泡沫槍裝置。 FSS規(guī)則對手提泡沫槍的具體性能和組成進行了規(guī)定,總結如下: 1.該設備基本構成是:連接水龍(fire hose)+槍(a foam nozzle)+20L充滿泡沫液的容器(a portable tank containing at least 20 liters of foam concentrate)+20L充滿泡沫液的備用容器(spare tank of foam concentrate of the same capacity.) 2.泡沫液應被主管機關認可,也即:有證書 3. 泡沫溶液的流量至少為200 l/min,適合撲滅油類火 常見的缺陷是:船員不會使用手提泡沫槍裝置,備用泡沫液缺失,或者槍缺失,或者水龍跟消防主管路連接不匹配,手提泡沫裝置位置不正確(有的沒有放在鍋爐艙內(nèi)或入口)等。 這里需要注意的是,以往有朋友咨詢手提泡沫液是否需要盛滿泡沫液,我理解是需要的,盡管上文1983修正案,我標黑的位置,只提到了一個備用容器(spare tank),考慮到83修比較古老,應以最新的修正案為準,回到FSS code原文:A portable foam applicator unit shall consist of a foam nozzle/branch pipe, either of a self-inducing type or in combination with a separate inductor, capable of being connected to the fire main by a fire hose, together with a portable tank containing at least 20 liters of foam concentrate and at least one spare tank of foam concentrate of the same capacity. 第一、公約中對使用的泡沫桶和備用的,均使用了foam concentrate 這個詞組,備用和再用的要求應該是一致的; 第二、由于消防設施要求立即可用,一般手提泡沫裝置,再用容器應充滿泡沫液,容易造成泡沫盛放裝置損壞或者失效等,備用的目的是以防不時之用。 對于有的朋友不會使用手提泡沫槍裝置的,PSCReady為大家整理了一期視頻,供大家觀賞,高手請忽略。 |
|
來自: 踏雪無痕zmbk92 > 《psc》